2026
Dec 2026
Journal of the Brazilian Society of Mechanical Sciences and Engineering
Springer Science and Business Media LLC
Vol. 48 · No. 16 · Article 1119
ISSN 1678-5878
https://link.springer.com/content/pdf/10.1007/s40430-026-07110-1.pdf
en
Mechanical Engineering · COPPE/UFRJ
Jorge A. Aguilera; Gustavo C. R. Bodstein; Gustavo R. Anjos
Dec 2026
Journal of the Brazilian Society of Mechanical Sciences and Engineering
Springer Science and Business Media LLC
Vol. 48 · No. 16 · Article 1119
ISSN 1678-5878
https://link.springer.com/content/pdf/10.1007/s40430-026-07110-1.pdf
en
Abstract Gas transmission systems normally experience operating conditions that differ from those anticipated during compressor design. In some cases, market evolution leads to sustained throughput levels below the original design range of centrifugal compressors. Under these low-flow and low-head conditions, anti-surge recirculation is no longer a transient protective action but a permanent component of operation. Despite its practical importance, the minimum-energy operating condition in this regime remains poorly understood and insufficiently characterized in the literature. The objective of this work is to identify and characterize the energy-optimal operating point of centrifugal compressors under sustained recirculation. The methodology adopted is based on a physics-based model combining real-gas thermodynamics, compressor performance maps, surge-margin requirements, and minimum-speed constraints; the optimal operating condition is obtained analytically by differentiating shaft power along the compressor operating trajectory, and a second-order analysis yields an operational tolerance. A comparative analysis of the model results against manufacturer-certified field data from three industrial compressors shows mean absolute percentage errors below 3%, and reveals a characteristic V-shaped relationship between shaft power and operating pressure ratio, arising not from surge dynamics but from the competition between surge-margin and minimum-speed driven recirculation requirements as throughput decreases. The vertex of this curve satisfies a closed-form optimality condition based on unit logarithmic elasticity between isentropic head and processed flow, with an operational tolerance of approximately 0.55 kgf/cm 2 for a 5% power-increase budget. In conclusion, operating at the vertex reduced shaft power, fuel-gas consumption, and CO 2 emissions by 27-34% at fixed throughput, without hardware modifications and without approaching surge. To the authors’ knowledge, this is the first closed-form analytical characterization of the minimum-energy condition for centrifugal compressors operating under sustained recirculation, and it provides a physically interpretable tool for energy-efficient operation in the permanent low-flow/low-head regime.